<?xml version="1.0" standalone="yes"?>
<Platform PlatformId="74">
  <Description>Kaskaskia River at Shelbyville TW, IL</Description>
  <Agency>CEMVS</Agency>
  <IsProduction>false</IsProduction>
  <Site>
    <Latitude>39-24-25 N</Latitude>
    <Longitude>88-46-50 W</Longitude>
    <Elevation>530.0</Elevation>
    <ElevationUnits>ft</ElevationUnits>
    <Timezone>CST6CDT</Timezone>
    <Country>USA</Country>
    <State>Illinois</State>
    <NearestCity>Shelbyville Tw</NearestCity>
    <Region>Kaskaskia River</Region>
    <SiteName NameType="local">CE620514</SiteName>
  </Site>
  <PlatformConfig ConfigName="MVS-602-SB---55">
    <Description>MVS \nStage Battery \n60 minute 2 lines</Description>
    <ConfigSensor SensorNumber="1">
      <SensorName>STAGE</SensorName>
      <DataType Standard="SHEF-PE" Code="HG"/>
      <RecordingMode>F</RecordingMode>
      <RecordingInterval>01:00</RecordingInterval>
      <TimeOfFirstSample>00:00</TimeOfFirstSample>
    </ConfigSensor>
    <ConfigSensor SensorNumber="2">
      <SensorName>BATTERY</SensorName>
      <DataType Standard="SHEF-PE" Code="VB"/>
      <RecordingMode>F</RecordingMode>
      <RecordingInterval>01:00</RecordingInterval>
      <TimeOfFirstSample>00:00</TimeOfFirstSample>
    </ConfigSensor>
    <DecodesScript ScriptName="ST">
      <ScriptType>Decodes</ScriptType>
      <DataOrder>A</DataOrder>
      <FormatStatement Label="st">
        /,2(F(S,A,5,1),1X,F(S,A,5,2),/)
      </FormatStatement>
      <ScriptSensor SensorNumber="1">
        <UnitConverter FromUnitsAbbr="raw" ToUnitsAbbr="feet">
          <Algorithm>none</Algorithm>
        </UnitConverter>
      </ScriptSensor>
      <ScriptSensor SensorNumber="2">
        <UnitConverter FromUnitsAbbr="raw" ToUnitsAbbr="volts">
          <Algorithm>none</Algorithm>
        </UnitConverter>
      </ScriptSensor>
    </DecodesScript>
  </PlatformConfig>
  <TransportMedium MediumType="goes-self-timed" MediumId="CE620514">
    <DecodesScript ScriptName="ST"/>
    <EquipmentModel Name="HA570">
      <EquipmentType>DCP</EquipmentType>
      <Company>Handar</Company>
      <Model>570A</Model>
      <EquipmentProperty PropertyName="PlatformType">DCP</EquipmentProperty>
      <EquipmentProperty PropertyName="RetrievalMethod">DCP</EquipmentProperty>
      <EquipmentProperty PropertyName="TimeOrder">A</EquipmentProperty>
    </EquipmentModel>
    <ChannelNum>73</ChannelNum>
    <AssignedTime>00:37:30</AssignedTime>
    <TransmitWindow>00:00:30</TransmitWindow>
    <TransmitInterval>01:00</TransmitInterval>
    <Preamble>L</Preamble>
    <TimeZone>CST6CDT</TimeZone>
  </TransportMedium>
  <PlatformSensor SensorNumber="1">
  </PlatformSensor>
  <PlatformSensor SensorNumber="2">
  </PlatformSensor>
</Platform>